Product Description
TMQ. CV Series Table Top Pulsation Steam Vacuum Sterilizer Application: With pressure steam as medium, it is used in sterilizing medical dressing, utensils, class A, Class B hollow lumen instruments, catheters, and waste in the operating room, clinic department, CSSD, biological laboratories and other healthcare sectors. Main Features: · PLC control technology, colored touch screen; · Affusion, pulse vacuum, heating, sterilizing, exhaust, vacuum drying whole process are automatically controlled by program; · Dynamic pulsant vacuum exhaust air: Vacuum up to-0.08MPa, can exhaust steam in medical dressings, Class A hollow lumen instruments; · Pulsation behind vacuum drying system to ensure parcels dry. · High-performance built-in steam generator and steam-water separator devices, ensure quality steam, without external steam source; · With instruments, dressing, rubber and customized procedures for user's optional; · With manually Bowie & Dick leaking and vacuum testing procedures; · 0.22μ M HEPA filter can ensure the vacuum steam is amicrobic, to avoid further contamination; · Dynamically LCD display temperature, pressure, time, sterilizing status, malfunction alarm; · Equipped with maintenance reminding function. User-friendly maintenance equipment and replacement of wearing parts; · Beep reminding when finishing; · Mini printer is optional to real-time record the whole sterilizing process and malfunction informations. Safety Protection: · Over-temperature protection: Over the setting temperature, system automatically cut off power and display alarm; · Door safety interlock devices: Only the doors closed in place, sterilizers to start working procedures. If there is dangerous pressure in the chamber, the door can not be opened; · Dual overpressure protection: Automatic releasing safety valve: If pressure is over design, safety valve will open to release; Overpressure automatic protection control: If pressure is over setting, safety valve will automatic release and display alarm; · Anti-dry alarm: Below the water level, automatically cut off the heating power, and display alarm information; · Electronic circuit safety devices: AC main circuit with a short-circuit protection, over-voltage DC control circuits with overload protection. Main Technical Parameters: Designed Pressure: -0.1/0.28MPa Max. Working Pressure: 0.23MPa Pressure Display Precision: ± 0.1KPa Sterilization Temperature Range: 105º C~136º C Temperature Display Precision: ± 0.1º C Temperature uniformity: ≤ ± 0.5º C Chamber Material: SUS304 stainless steel Volume: 60L Chamber Dimension(Φ XL): 380x500mm Outer Dimension(LxWxH): 985x736x676mm N. W.: 105Kg Voltage: 380V Frequency: 50Hz Power: 5.0Kw